BH3F
Rated load | t | 0.05/0.1/0.25/0.5/0.75/1/1.5/2/2.5/5 |
lb | 200/250/300/500/750/1 K/1.5K/2K/2.5K/3K/5K/7.5K/10K/15K/20K | |
Accuracy | C3 A5S B10S | |
Maximum number of load cell verification intervals | nmax | 3000 III5000 IIIL10000 |
Minimum load cell verification interval | Vmin | Emax/10000 Emax/15000 Emax/10000 |
Composition Error | (%FS) | ≤ ±0.020 ≤ ±0.018 ≤ ±0.035 |
Creep | (%FS/30min) | ≤ ±0.016 ≤ ±0.012 ≤ ±0.030 |
TC Span | (%FS/10°C) | ≤ ±0.011 ≤ ±0.009 ≤ ±0.030 |
TCO | (%FS/10°C ) | ≤ ±0.015 ≤ ±0.010 ≤ ±0.030 |
Sensitivity | (mV/V) | 3.0 ±0.008 |
Input Resistance | (Q) | 380 ±5.0 |
Output Resistance | (Q) | 351 ±3.0 |
Insulation Resistance | (MQ) | ≥5000(50VDC) |
Zero balance | (%FS) | ≤ ±1.0 |
Temperature compensation range | (°C) | -10 ~ +40 |
Service Temp Range | (°C) | -35 〜+70 |
Recommended excitation voltage | (V) | 5 〜12(DC) |
Maximum excitation | (V) | 18(DC) |
Safe Load Limit | (%FS) | 150 |
Breaking Load Limit | (%FS) | 300 |
boundary dimension mm(inch)
H | L | W1 | W | H 1 | M | |
50kg, 100kg | 76.2(3.0) | 50.8(2.0) | 19(0.75) | 22.4(0.88) | 9(0.35) | M10x1.5 |
250kg ~ 750kg | M12x1.75 | |||||
1.0t,1.5t | 25.4(1.0) | 28.8(1.13) | ||||
2.0t 〜5.0t | 108(4.25) | 76.2(3.0) | M18x1.5 | |||
250lb | 76.2(3.0) | 50.8(2.0) | 12.7(0.5) | 16.1(0.63) | 9(0.35) | M20x1.5 |
200lb ~ 300lb | 19(0.75) | 22.4(0.88) | ||||
500lb ~ 1.5klb | M33x3 | |||||
2klb ~ 3klb | 25.4(1.0) | 28.6(1.13) | ||||
5klb ~ 10klb | 108(4.25) | 76.2(3.0) | 3/4-16UNF | |||
15klb | 140(5.51) | 100(3.94) | 31.8(1.25) | 35(1.38) | 16.5(0.65) | 1-14UNS |